DP45 -
Validyne Engineering
The Validyne DP45 Very Low Differential Pressure Transducer is designed for extremely low pressure measurement in the order of 1 inch water column. This instrument is used extensively in connection with flow measurements where dynamic response at low flow rates is required. Dynamic line pressure effects are minimized due to the combination of low internal volume, symmetrical construction, and small volumetric displacement inherent in the DP45 design.
-
CM Envirosystems Pvt Ltd
The Drive-In Rain Test Chamber is generally used to conduct whole body testing of assembled vehicles under different rain test procedures to study and estimate their structural degradations and destructions induced by rain/water. The twin shower area with 1.1 million litre & 0.35 million litre volume is enclosed in a shed where arrays of pipes are interconnected to form zones to ensure the uniform spraying as per JSS 55555 test standard. The water gushes through the nozzle at a flow rate of up to 288 cu m/hr and the test chamber water collection system have a central grating with sufficient slope to collect the sprayed water during operation and circulate it back to the water reservoir to ensure close loop circulation.
-
Campbell Scientific, Inc.
Campbell Scientific offers a variety of sensors to measure water level, stage, and flow: pressure transducers, shaft encoders, radar ranging sensors, sonic ranging sensors, and bubblers. Users often select their sensors based on the site location, required accuracy level, and ease of installation.
-
IPX34 -
Shenzhen Chuangxin Instruments Co., Ltd.
The Spray Tester IPX 3/4 is a hand-held test device to verify protection against spraying and splashing water. The water pressure can be adjusted using the flow control knob on the device to give the required flow rate.
-
Shenzhen Chuangxin Instruments Co., Ltd.
IEC60529 IPX1-IPX2 vertical drop testerIPX1 uses the vertical drop of water tank, shell in the speed of 1r/min turntable, turntable axis and the specimen axis distance eccentricity is about 100mm, the water flow is 1mm/min, duration of 10 minutes. IPX2 uses the vertical drop of water tank, shell four fixed positions in the tilted 15 degrees, table does not turn, the water flow of 3mm/min, eac
-
Shenzhen Chuangxin Instruments Co., Ltd.
IEC60529 IPX5/6 Water Jet Nozzle is designed according to the requirements of IPX5 and IPX6 code of GB4208 and IEC60529 standard. IEC60529 IPX5/6 Water Jet Nozzle is used to test the waterproof performance of the appliance and electronic. The IEC60529 IPX5/6 Water Jet Nozzle consists of a jet handle that is equipped with a pressure gauge and an easy-to-adjust flow valve. The interchangeable nozzles assemble easily to the jet handle. The nozzles are made from stainless steel.
-
ULP-27 -
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Temperature Control Loop Setup is basically a PC based PID controller setup used for closed loop and open loop analysis of temperature process system. The setup comprises of RTD temperature Sensor. The water flows through the Rotameter and Process tank to which a heating coil is fitted. The heater is controlled by a Thirstier drive. The Thirstier drive is connected to PID controller. The manual control valve can control the water flow. The system is mounted on a tabletop model with all necessary Piping. Water at approx. 100 LPH has to be supplied to a system externally. The electronic panel comprises of ADC/DAC card with RS-232 interfaces.
-
ULP-25O & ULP-25T -
Unitech Scales And Measurements Pvt. Ltd
Flow Control Setup Comprises of a Orifice with DPT to measure flow Rate. The flow of water is controlled by Control Valve with pneumatic actuator. I to P converter is provided to control the actuator. Rotameter is provided to measure actual flow rate. The system is mounted on a table top model with all necessary piping.
-
DVS Resolution -
Surface Measurement Systems
DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.
-
PAO -
Bemco Inc.
PAO, a fluid that does not react with water and is compatible with most metals, is the basis of the Bemco PAO-II series of fluid conditioners. Similar to the Bemco PCL Chillers, PAO-II Liquid Chillers are furnished as free standing caster mounted systems, ready to provide a reliable and precisely controlled flow of temperature conditioned PAO fluid. These systems are optimized for use with Polyalphaolefin fluid in an Aerospace environment.
-
WXU -
CKD Corporation
An integrated unit that integrates the flow sensor and valve of the circulation circuit of the cooling water.The complicated piping design around water and the number of man-hours for piping work are greatly reduced, and the footprint is reduced by 80% to save space in the system.
-
SCI-552 -
Teledyne Advanced Pollution Instrumentation
The SCI-552 is a system controller for ozone delivery systems that provides electronic control interfaces for a number of typical system components, including: ozone generators, EV valves, mass flow controllers, back-pressure controllers, Teledyne API 452 ozone sensors, Teledyne API 470 dissolved ozone sensors, and a water chiller.
-
DP Measurement
The AC6 Manometers are available in standard or high pressure versions. The AC6-SP Manometer can be used to measure differential pressure in the range 0.5-200 KPa and the AC6-HP Manometer operates in the differential pressure range 2-600 KPa. These electronic water system commissioning test sets have in built valve and orifice plate Kv values which enables the instrument to calculate and display flow rates during commissioning.
-
YOUNIO
Key structure is made up of rotary carried helical blades which goes around as the same direction of water flow.
-
Wewon Environmental Chambers Co, Ltd.
The industrial chiller is a kind of cooling water equipment which can provide constant temperature, constant water flow speed and water pressure. Industrial process chiller is usually a closed loop system, which can provide instantaneous cooling for the factory or lab production process and save water by recirculating cooling.Industrial chiller system be divided to low temperature chiller and normal temperature chiller in the temperature control. The normal temp is generally controlled within the range of +4 ℃ to +35 ℃. The low temperature water chiller is generally controlled in the range of 0 ℃ to -100 ℃.https://www.wewontech.com/industrial-chiller/